Ericsson MPI-II VHF Bedienerhandbuch Seite 1

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Audioverstärker Ericsson MPI-II VHF herunter. Ericsson MPI-II VHF Programming instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Mobile Communications
SERVICE SECTION
FOR
MPI-II VHF PERSONAL RADIO
Printed in U.S.A.Copyright January 1991, Ericsson GE Mobile Communications, Inc.
Maintenance Manual
LBI-38557A
Ericsson GE Mobile Communications Inc.
Mountain View RoadLynchburg, Virginia 24502
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - Maintenance Manual

Mobile CommunicationsSERVICE SECTIONFOR MPI-II VHF PERSONAL RADIOPrinted in U.S.A.Copyright January 1991, Ericsson GE Mobile Communications, Inc.Maint

Seite 2 - DISASSEMBLY PROCEDURE

2. A full charge cycle using an appropriate Ericsson GEcharger.3. This procedure should be repeated again. Performingthe rated discharge and charge cy

Seite 3

INTRODUCTIONThis service section contains the necessary informationto align and troubleshoot the MPI-II (136-174 MHz) Per-sonal Radio. This manual inc

Seite 4

FRONT COVER1. Remove the battery as described in the previoussection.2. Remove the two screws at (A) (See Figure 2).3. Carefully lift the front cover

Seite 5 - LBI-38557 LBI-38557

Several tests are presented which will help isolate a pos-sible RF or control circuit problem. The control circuits, whichare located on the T/R Board

Seite 6

Figure 4 - Location of Tuning Controls and Test PointsLBI-38557 LBI-385574

Seite 7

2. Check power on the lower channel. Adjust C124 in thedirection that increases power output to a level half waybetween the initial lower and upper ch

Seite 8 - COMPONENT REPLACEMENT

3. Check for proper operation of the synthesizer. Thereshould be approximately 0 dBm drive level on theSYNTH output line for proper transmit operation

Seite 9 - PREVENTATIVE MAINTENANCE

D.C. AnalysisBattery voltage (7.5/10 Volts, B+) is supplied to a 5.4 voltregulator circuit consisting of transistors Q801, Q802 andQ803. Diode regulat