Connecting the Equipment to the AC Power Supply
As there is no mains power switch fitted to this chassis, ensure the local AC power supply is switched OFF before connecting the
supply cord.
Connect the mains lead to the equipment and then to the local supply.
Power Consumption
Rated current 4.0 – 2.0 A
Power consumption: 350W (Actual power consumption is dependant on the option cards fitted, see Table of Typical Power
Consumption).
See also Technical Specification>Chassis>Power Supplies, Technical Specification>* VCM>Power Supplies.
Protective and Technical Earths
Protective Earth
WARNING!
This unit must be correctly earthed as described below.
This unit must be correctly earthed through the moulded plug supplied. If the local mains supply does not have an earth
conductor do not connect the unit. Contact Customer Services for advice.
Before connecting the unit to the supply, check the supply requirements.
Technical Earth
The terminal marked at the rear panel is a Technical Earth. Its use is recommended. This is NOT a protective earth for electric shock
protection.
UK (BS 1363) EUROPE (CEE 7/7) USA (NEMA 5-15P)
Earth Green and yellow Green and yellow Green
Neutral Blue Blue White
Live Brown Brown Black
Typical Power Consumption
Item Description
Power
VP/CHASSIS/1AC 1U Base Chassis (AC) 40 W
VP/CHASSIS/2AC 1U Base Chassis (Dual AC) 45 W
VP/HWO/EN8190/ENC EN8190 HD H.264 VCM 120W
VP/HWO/EN8100/ENC EN8100 SD MPEG-2 VCM 45 W
VP/HWO/EN7100/ENC EN7100 SD MPEG-2 VCM 45 W
VP/HWO/EN8130/ENC EN8130 SD H.264 VCM 40 W
VP/HWO/EN8180/ENC EN8180 HD MPEG-2 VCM 40 W
VP/HWO/ASI2IN2OUT ASI I/O Module 12 W
VP/HWO/EXTSYNC External Sync Option Module 0.2 W
© Ericsson AB 2011. All rights reserved