MAINTENANCE
PREVENTIVE MAINTENANCE
To ensure high operating efficiency and to prevent me-
chanical and electrical failures from interrupting system opera-
tions, routine checks should be made of all mechanical and
electrical parts at regular intervals. This preventive mainte-
nance should include the checks as listed in the table of Main-
tenance Checks that follows.
ASSEMBLY AND DISASSEMBLY
Easy access to the station is inherent in this design. Simply
unlock the door and swing it open. The station and radio pack-
age are hinged so that they can swing out for servicing.
To release the entire station and allow it to swing out, re-
move the three screws on the left that secure the chassis to the
cabinet brace. Then press the spring clip.
Loosening the right side radio mounting screws allows the
radio package to hinge open, providing access to the Remote
Board, Interconnect Board, and Option Boards.
Remote Board
To remove the Remote Board, remove the POZIDRIVOR
screw in the four corners of the board and remove the board.
Unplug cabling as necessary.
Interconnect Board
To remove the Interconnect Board, remove the four screws
securing it to the chassis and disconnect all cabling. Remove
the Interface Board and/or the Keypad Board if necessary.
OPTION INSTALLATION
INSTRUCTIONS
Most options are radio options, and are thus the same in
both installation and operation when the radio is used in the
Wall Mount application. Refer to the applicable Maintenance
Manual for mobile radio options.
BATTERY STANDBY OPTION
An external battery can be used to power the station in the
event of AC power failure. The battery and charger must be
supplied by the customer. The standby option consists of Op-
tion Cable Assembly 19B802942. Refer to the Battery
Standby Option Application Assembly for installation.
INITIAL ADJUSTMENT AND
CHECKOUT
After the station has been installed as described in the In-
stallation Manual, the following adjustments should be made
by an authorized electronics technician.
TEST EQUIPMENT REQUIRED
1. Deviation Monitor
2. Wattmeter, 50 ohms, 150 Watts
3. RF Generator, (Station RF Frequencies)
4. AC Voltmeter
5. 30 dB Decoupler
TRANSMITTER ADJUSTMENT
The adjustment for the transmitter includes measuring the
forward and reflected power, adjusting the antenna length for
optimum ratio, and then setting the transmitter to rated power
output. Next, measure and record the frequency and modula-
tion for future reference. For complete transmitter adjustment,
refer to the Alignment Procedure in the applicable radio unit
Maintenance Manual.
RECEIVER ADJUSTMENT
Initial adjustment for the receiver includes adjusting the
audio output power for 3 watts across the speaker. Refer to the
Maintenance Manual for the radio being used for Trou-
bleshooting and Alignment Procedures, or Adjustments.
STATION ADJUSTMENT
PROCEDURES
Your station was adjusted at the factory. If adjustment is
needed due to board replacement, or other reasons, perform the
following steps.
REMOTE SETUP
Receiver to Line
1. Turn ON Power and Speaker switches.
2. Set REMOTE and INTERCOM switches to OFF.
3. Connect the RF Generator to the station. Set the proper RF
frequency and a 1 kHz tone at 3 kHz deviation.
4. Connect the proper RCN1000 Remote Controller to J11 on
the rear of the station chassis.
5. No tone should be present at the Remote Controller.
6. Turn on the REMOTE switch. A tone should be present
at the Remote Controller.
a. On the Tone Remote Board (19A704686P6) set R35
for 0 dBm at J1-3 and J1-4.
b. On the EDACS Tone Remote Board (19A704686P8)
set R66 for 0 dBm at TB1-2 and TB1-5.
7. Turn OFF the station REMOTE switch. Disconnect the
RF Generator and connect the wattmeter to the station
through the 30 dB decoupler.
8. Apply a 30 mVRMS 1 kHz tone across J101-1 Desk Mic
Hi and J101-2 Desk Mic Lo.
9. Ground J101-3 Desk Mic PTT. Measure the RF power
on the wattmeter.
10. With J101-3 grounded, check for 20 to 43 mVRMS, 1
kHz tone across J209-5 (Mic Hi) and J209-7 (Mic Lo).
Check to verify that no tone is present at the Remote
Controller. Remove the ground. (An isolation trans-
former may be required.)
11. Switch the INTERCOM switch ON. Ground J101-3
Desk Mic PTT. Check to verify that the radio does not
key (no power on the wattmeter). Check to verify that a
tone is present at the Remote Controller. Press the IN-
TERCOM switch to the MOM position and check for a
tone at the Remote Controller. Release the INTERCOM
switch.
a. On the (931) Interface Board, set R323 for 0 dBm at
J1-3 and J1-4 on the (686P6) Tone Remote Board..
b. On the (931) Interface Board, set R323 for 0 dBm at
TB1-2 and TB1-5 on the (686P8) PST Remote Board.
Line to TX
1. Set Station Remote switch and InterCom switch to OFF.
2. Apply 1 kHz at 120 mV to Microphone input of the Con-
troller.
3. On the Controller, press SF5 on EDACS only, and
ground PTT. Check to see that the Radio is not keyed.
4. Switch the Station Remote switch ON. Key the Control-
ler. Check to see that the radio is keyed.
5. The Controller should be preset to 0 dBm.
a. On the 686P6 PST Remote Board, set R60 for 60
mVRMS at J209-5 and J209-7.
b. On the 686P8 PST Remote Board, set R82 for 60
mVRMS at J209-5 and J209-7.
6. Before leaving the station, make sure the INTERCOM
and SPEAKER switches are OFF, and the REMOTE
switch is ON.
TABLE OF MAINTENANCE CHECKS
INTERVAL BETWEEN CHECKS
Every Six Months As Required
Transmitter Alignment - Compare meter readings with voltages read during
initial tune up. Check power output. (See Alignment Procedure for
Transmitter.)
X
Receiver - Retune the front end and check meter readings taken during
initial tune-up. (See Alignment Procedure for Receiver.)
X
Transmission Line - Check for positive indication of pressure on
transmission line pressure gauge (if pressurized line is used).
X
Antenna - Check antenna and mast for mechanical stability. X
Mechanical Inspection - Visually check cables, plugs, sockets, terminal
boards, and components for good electrical connection. Check for tightness
of nuts, bolts, and screws to make sure that nothing is working loose from
its mounting.
X
Cleaning - Use a vacuum cleaner to remove accumulated dust inside the
cabinet.
X
Frequency Check - Check transmitter frequency and deviation as required. X
The battery standby option does not recharge the bat-
tery.