LBI-39039
22
3.4.2. Extension Equipment
Extensions are initiated with the command EXTEI, and 4001 through 4008 are initialized.
EXTEI
DIR
4001&&4008
CAT
0
EQU
LIM 1
Magazine X X must be entered in the script file
Board Position XX XX must be entered in the script file
Board Individual 0
TYPE
EL6
TRM
Transmission Category 0 No attenuation or amplification
ICAT
Instrument Class 000 EL6 analog
Instrument type 0 Hookflash capable, normal intercept tone and normal
ringing
ADC
Bearer services 0 Speech and 3.1 KHz
CLI request 0 Not requested
CLI presentation 0 Allowed
Call metering 0 Not in US (Per route)
Malicious call trace 0 Not in US
Manual message waiting 0 Not allowed
Transfer outgoing calls 0 Not allowed to accept transferred or to transfer
outgoing external calls
Authorization code 0 Does not need to match extensions
Network affiliation 0 Common public number sent to network
3.5. COMMON ABBREVIATED DIALING NUMBERS
Common Abbreviated Dialing (CAD) numbers are common speed dial numbers. An extension's or route's CAD class
determines which CAD numbers it may use. The CAD classes are assigned as follows:
CAD CLASS
Extensions 0
EDACS Routes 1
Private Network Routes 2
Public Network Routes 3
3.5.1. Extensions and EDACS to Public Network
ADCOI
ABB
Abbreviated number
4XXX XXX must be entered in the script file and will be between 100 and
999
TRA
Translated number
9XXXX XXXX must be entered in the script file and will be between 1 and 19
digits
CLASS
0&1 Allowed for Extensions and EDACS to Public Network
Kommentare zu diesen Handbüchern