Ericsson LBI-39001 Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 58
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
LBI-39039
5
2. INTERFACES AND REQUIREMENTS
2.1. EDACS INTERFACE
An EDACS-originated call appears to the MD110 as an incoming DID call from an external T1/E1 ISDN trunk. One
external T1/E1 ISDN trunk is dedicated to EDACS; it is a TLU-63/1 (T1) or TLU-64/1 (E1) board in the MD110. This
allows 23/30 simultaneous calls.
For calls to the PSTN, the number begins with an LCR code.
For calls to MD110 extensions, the number is the extension number.
2.2. PSTN/PBX INTERFACE
A PSTN-originated call appears to the MD110 as an incoming trunk call. This interface can be analog or digital, and it
can be a CO, DID, or a tie trunk. A PBX-originated call appears to the MD110 as an incoming trunk call. This interface can
be analog or digital, and it can be a tie trunk.
Minimum Requirements for the PSTN/PBX Trunks
The ability to perform end-to-end tone signaling while in the connected state.
The ability to properly send and receive call clearing signals.
DID to radios requires trunks capable of passing dialed digits to the MD110.
Trunks or lines with forward and backward line clearing are highly recommended. See the explanation below.
With Line Clearing Without Line Clearing
When the Network hangs up, the interconnect call
will clear and free interconnect and radio resources.
When the Network hangs up, the radio must clear the
interconnect call or let it clear due to hang-time expiration or
conversation limit expiration to free interconnect and radio
resources. This problem would be very significant for full
duplex calls, since the user must clear the call or the call will
clear only after the conversation limit expiration.
With B-Answer Without B-Answer
Radios will hear IMC-generated ringback for
outbound calls.
Ringing duration on outbound calls will be
limited to 30 seconds by the PI.
In applications where billing is performed, the
customer will not be billed unless the called
party answers.
Radios will hear MD110 or Network ringback for
outbound calls.
Ringing duration on outbound calls will not be limited
by the PI.
In applications where billing is performed, the customer
will be billed for calls even if the called party does not
answer.
T1 or E1 tie trunks are highly recommended for connecting the MD110 to another PBX.
Calls to EDACS require DISA access and the radio ID, and may require an LCR code. Calls to MD110 extensions
require an extension number.
Seitenansicht 4