13
A CALL IS UNSUCCESSFUL OR A CALL IN
PROGRESS IS INTERRUPTED
An error signal (a short beep) is heard. Observe the
SERV indication in the display. Refer to Appendix 1 in the
Operator’s Manual for further information.
ANSWERING AN INTERCONNECT CALL
1. When you are being called, the telephone rings
according to the setting in the Menu Mode. The back
light flashes Green while "CALL" also flashes in the
display. Press
to answer. The TX and B4 symbols
will light up and CALL will be removed.
2. When the conversation is finished, press
.
Figure 9 - Receiving A Call
UNANSWERED CALL COUNTER
If one or more calls have not been answered, the
number of unanswered calls will be displayed. For example,
02 CALLS. The unanswered call counter will reset as soon
as you press any key.
TURNING THE RADIO OFF
Press and hold down the key until you hear a beep. If a
call is in progress, end the call by pressing and releasing the
key, wait a few seconds, and then press and hold down
the
key until you hear a beep.
SERVICE SECTION
This Service Section provides the information necessary
for proper care and maintenance to obtain optimum
performance of the IPE radio. In addition, this section
provides the steps to:
Program the radio (personality and flash)
Troubleshoot the radio (determine if a problem is
hardware or software)
Disassemble and reassemble the radio
Replace the circuit board
When using the Troubleshoot Box with a IPE radio,
never place the
SERVICE
switch in the 12V position.
CAUTION
As stated previously, field repairs are limited to removal
and replacement of the printed circuit board and the
miscellaneous parts shown.
The following is a complete list of the equipment required to
program or service the IPE radio:
Equipment Description Part Number
1. Troubleshoot Box (includes):
Test Cable
DB9 (male) to DB9 (female) Cable
KRY 101 1612
KRY 101 1612/52
KRY 101 1612/53
2. TEK Box and Utility Software
(includes):
PC Interface Cable
Interface Adapter Cable
LPP 106 27
3. Alexander 4 Connector
KRY 101 1062
4. Small Phillips screwdriver
customer supplied
5. flat blade screwdriver
customer supplied
IBM PC/XT/AT/286/386/486 or any
true compatible with MS-DOS version
3.3 or later.
customer supplied
PREVENTIVE MAINTENANCE
Keep the exterior of the radio clean. Use a soft damp
cloth.
To ensure efficient power transfer from the battery to
the radio, periodically wipe the contacts of the battery
and radio to remove dirt or grease. Use a soft dry cloth.
NOTE