Created by ESF/KEP/MA Francois Vaillant
Up to now, the H.323 codecs list is defined in a static way inside MDE H.323
software:
o Choice 1 = G.729AB (silence suppression)
o Choice 2 = G.729A (no silence suppression)
o Choice 3 = G.729B (silence suppression – idem G.729AB)
o Choice 4 = G.729 (no silence suppression – idem G.729A)
o Choice 5 = G.723 (6.3 kbits/s)
o Choice 6 = G.711A (64 kbits/s, A-law)
To avoid problems when inter working with some H.323 terminals (for instance,
DRG22i terminal), the release R8.1 allows redefinition of the H.323 codecs list
using administration tools. The order of the codecs may be changed. Some
codecs may be missing. Control is done by administration toll in order to avoid
multiple occurrences of the same codec. A new codec is added: G.711U
(64kbit/s) for North American markets.
For information, codecs used by H.323 endpoints handled by MDE are:
o Ericsson IP phones D442x: G.711A, G.711U, G.729A,
G.729AB and G.723.
o DRG22i: G.711A, G.711U, G.729, T.38 fax
o MD110: G.729AB, G.729B, G.729A, G.729, G.723, GSM,
G.728, G.711A 56 kbits/s, G.711U 56 kbits/s, G.711A 64
kbits/s, G.711U 64 kbits/s
New commands for diagnostics & maintenance
The new tool allows making Ethernet traces, saving them in files on the
Flashcard and retrieving them in remote administration. This gives a powerful
tool for diagnostic and maintenance. Two new commands are available:
o One for recording of traces in a file
o Another one to get Ethernet integrated trace
New localization procedure for MD Evolution / EBN
Coming from the factory, the system is loaded with the latest stable CPU release and
with a DSP software for France with French announcements. For adapting the MD
Evolution/ EBN system to the country specificities, it is necessary to :
1. Load the DSP software adapted to the language and country of destination,
2. Re-initialize the Database to default values adapted to this new country.
This could be automatically done using a country specific Compact Flashcard.
The procedure for updating the local system with this dedicated country
Flashcard is as follows: