Ericsson Internal
PRODUCT SPECIFICATION 4 (5)
Prepared (also subject responsible if other) No.
MICMALE 3/1301-BMR 603 1203/1 Uen
Approved Checked Date Rev Reference
EAB/FJB/GKF (Natalie Johansson) (MICANWO)
2008-09-05 C
Thermal Consideration continued
Definition of reference temperature (T
ref
)
The reference temperature is used to monitor the temperature
limits of the product. Temperatures above maximum T
ref
are
not allowed and may cause degradation or permanent
damage to the product. T
ref
is also used to define the
temperature range for normal operating conditions.
T
ref
is defined by the design and used to guarantee safety
margins, proper operation and high reliability of the module.
Connections
24
12
1
13
Pin Designation Function
1 GND Ground
2 GND Ground
3 -IN Input voltage -48V
4 -IN Input voltage -48V
5 RC Remote control
6 GND Ground
7 GND Ground
8 N/C Not connected
9 Return1 Output 78V return
10 Out1 Output +78V
11 GND Ground
12 GND Ground
13 GND Ground
14 GND Ground
15 Out2 Output —52V
16 Out2 Output —52V
17 N/C Not connected
18 Out3 Output —33V
19 Out3 Output —33V
20 N/C Not connected
21 N/C Not connected
22 GND Ground
23 GND Ground
24 GND Ground
E
BMR 603 1203/1
DC/DC converters, Input 40-72 V, Output 78/-52/-33 V/32W
EN/LZT 146 393 R1E September 2008
© Ericsson Power Modules AB
Technical Specification