Ericsson Internal
PRODUCT SPECIFICATION 1 (5)
Prepared (also subject responsible if other) No.
MICMALE 2/1301-BMR 603 1203/1 Uen
Approved Checked Date Rev Reference
EAB/FJB/GKF (Natalie Johansson) (MICANWO)
2008-09-05 D
Absolute Maximum Ratings
Characteristics min typ max Unit
T
ref
Operating Temperature (see Thermal Consideration section) -40 +105 °C
T
S
Storage temperature -55 +125 °C
V
I
Input voltage -0.5 +75 V
Positive logic option -0.5 +75 V
V
RC
Remote Control pin voltage
(see Operating Information section)
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and
performance may degrade in an unspecified manner.
Fundamental Circuit Diagram
GND
GND
RC
Bias Regulator,
Control and
Supervision
OUT3
OUT2
OUT1
RETURN1
-IN
E
BMR 603 1203/1
DC/DC converters, Input 40-72 V, Output 78/-52/-33 V/32W
EN/LZT 146 393 R1E September 2008
© Ericsson Power Modules AB
Technical Specification