Front Panel LCD Menus
Table C.28: Remote Port Setup Menu
Menu title: SET:REMOTE
PORT
Description Section
Baud Rate:
Sets the baud-rate for the communication with
the external device.
75, 110, 110, 150, 200, 300, 600, 1050, 1200,
2400, 4800, 9600, 19200, 38400, 57600,
115200
Default = 115200.
----
Data Bits:
Sets the number of data bits used for each
character.
7 - The number of data bits is set to 7
8 - The number of data bits is set to 8
Default = 8.
----
Stop Bits:
This setting determines the time between each
character being transmitted (bits per second).
0.5 - 0.5 bps
1.0 - 1 bps
1.5 - 1.5 bps
2.0 - 2.0 bps
Default = 1.0.
----
Parity:
The parity bit setting defines the type of error
checking used.
None – No parity
Odd – Odd parity
Even – Even parity
Default = None.
----
Flow Control: Sets the flow control.
None – No flow control.
Note: Only one option is available
----
EN/LZT 790 0002/2