Alarm Categories and Conditions
D.2.2 ASI Input Alarms
The ASI input alarms relate to errors seen at the ASI input.
Table D.2: ASI Alarm Categories and Conditions
Alarm
Category
Contents
Alarm Description Remedy Default
ASI Input:
No sync
Will alarm if the receiver
can not lock to the
incoming transport
stream.
Check signal
source
A
Note: These alarms are only available when the ASI input module is fitted in the
receiver.
D.3 Output Stage Alarms
D.3.1 Video Output Alarms
The video output alarms relate to errors occurring in the video stream decoder.
Table D.3: Video Alarm Categories and Conditions
Alarm
Category
Contents
Alarm Description Remedy Default
No stream
input
No stream is detected in
the current TS.
Check input
source.
A
Error in
stream
There is an error in the
video stream.
Verify correct CA
system and
smart card.
A
Video
resync
There has been a
transition from “no frame
sync” to “frame sync
OK”.
A
Video output:
Video not
used
No video component
exists for the currently
selected service.
W
EN/LZT 790 0002/2 R1A