Operating the Equipment Remotely
Step Action Result
4.
Repeat for data bits, stop bits,
parity and flow control.
All settings should be set to match the
external control host.
5.
Once completed, the changes
take effect immediately.
When the communication parameters are entered correctly, set the system into
remote mode for the external computer to gain control of the unit.
Table 5.2: Activating RS-232 Remote Control
Step Action Result
1.
Go to the Control menu,
located under the Setup
menu.
The display will read “SET:CONTROL” on the top
line.
2.
Scroll until the item “Ctrl.
Mode” is shown.
3.
Press right once, and then by
using the up and down
arrows, key in the desired
control mode, in this case:
Remote”.
The unit is now ready to accept remote control
via the RS-232 port.
5.1.4 Setting Up Director Over-air Control
5.1.4.1 Overview
For the unit to be controlled via over-air control (OAC), the Director software license
must be enabled. The control mode of the unit must also be set to OAC.
Table 5.3: Activating Director Remote Control
Step Action Result
1.
Go to the Control menu,
located under the Setup
menu.
The display will read “SET:CONTROL” on the top
line.
2.
Scroll until the item “Ctrl.
Mode” is shown.
3.
Press right once, and then by
using the up and down
arrows, key in the desired
control mode, in this case:
OAC”.
The unit is now ready to accept over-air control.