Upgrading EQ8096 with Input and Output Option Cards
9.1 Introduction
This document defines the procedures installing and removing Input and Output
Option Cards.
9.1.1 Responsibilities
The operator should be capable to working to IPC-A-610 standards and follow
precautions set down in P035 Handling and Protection of ESD product.
In case of problems please contact customer services.
9.1.2 Tools Required
The following tools are required for installation and removal:
2 x S14483 Card Extraction Tools
9.1.3 Parts Required
The procedures given in this chapter refer to installation and replacement of the
parts listed in the following table
Table 9.1 Parts Required
Part Number Qty Description
EQ8096/HWO/12QAM A/R 12QAM Output Card
EQ8096/HWO/IP-RJ45 A/R Input Card with RJ-45 Connections
EQ8096/HWO/IP-SFP A/R Input Card with SFP Connections
9.2 Installing/Removing a 12QAM Output Card
When installing or removing the 12QAM Output Card from the EQ8096 Edge QAM,
the following process should be used.
9.2.1 Preparing the Unit
Before installing an Output Card the EQ8096 should be prepared, as follows:
1. Refer to Chapter 2, Installing the Equipment for slot numbering and assignment
information
2. Ensure the unit is disconnected from the AC or DC mains.
3. Maintain ESD precautions.
2/1553-FGC 101 1019 Uen A
9-3
Kommentare zu diesen Handbüchern