Alarms
The threshold value is determined by the global modulator settings, as this defines
the overall bit rate for each of the generated transport streams. An alarm is raised if
the total bit rate of all incoming UDP flows associated with a particular channel
exceeds this threshold level.
The status for each incoming transport stream can be seen under the TS
Construction Page. The status parameter will be in one of the following states:
Not locked: Indicating that the UDP port is not receiving any data.
Locked: Indicating that the UDP port is receiving data and the card is locked
onto a valid transport stream with a valid set of PAT and PMT(s).
No PSI: Indicating that the UDP port is receiving data and the card is locked
onto a valid transport stream without a valid set of PAT and PMT(s).
4.4.5 Temperature Alarms
The EQ8096 is forced-air cooled. The unit supports fan failure detection for any of
the 4 fans (card and PSU). It also provides internal temperature monitoring which is
configured to generate over-temperature alarms if a given threshold level is
exceeded. There is a separate temperature monitor on the main data input card and
each Modulator assembly.
Figure 4.7 Temperature Alarms Web Page
2/1553-FGC 101 1019 Uen A
4-7