Technical Specification
B.2.5.2 User Control Interfaces
The EQ8096 support control of user configurable parameters and the reporting of
status and alarms via SNMP, Telnet, RS-232 and HTTP.
Caution!
Only qualified Ericsson Field Service personnel shall use the telnet interface.
This exclusion does not exclude the use of the interface for setting the initial control
port IP address.
Only one Telnet connection to the card is permitted at any time. Simultaneous
control and monitoring from the Telnet, SNMP and HTTP interfaces is supported.
Where appropriate, user control parameter changes and status parameter changes
are reflected simultaneously on all control interfaces.
B.2.5.3 Control Parameters
All user control parameters are stored in non-volatile memory to allow restoration
from power up with no user intervention. Table B.8 provides a list of all user control
parameters that are directly related to the MPEG over IP application.
Table B.8 Control Parameters
Parameter Range Default value
Data port Physical
interface
1000BaseTX: GBIC 1000BaseTX
Time server IP
address
XXX:XXX:XXX:XXX 0.0.0.0
Time server control ENABLED: DISABLED DISABLED
Hours 0..23 0
Minutes 0..59 0
Date 1..31 1
Month 1..12 1
Time:
Entered as a compete
set of parameters.
Time shall auto
increment once
entered, or be
overwritten if a time-
server is enabled and
connected.
Year 1900… 2008
MAC layer CRC
control
ENABLED: DISABLED DISABLED
Transport Stream ID
for each generated
PAT
96 entries
0..65535 1..96
2/1553-FGC 101 1019 Uen A
B-8