Alarms
4.1 Introduction
This chapter describes the alarm aspects of the EQ8096, the functionality of the
Status indicator located at the rear panel (see Section 4.6) and the use of the SNMP
Traps (see Section 4.4.6). The EQ8096 supports the reporting of status and alarms
via SNMPv1/2 and HTTP protocols.
Note: The unit provides the user with a RED LED on the front panel to indicate an
alarm condition. This is lit when the global summary alarm is active.
Each alarm is configurable by all supported control interfaces in terms of:
Masked / unmasked
Alarm trigger (i.e. packet count, temperature threshold etc)
When an alarm is generated, the alarm module within the EQ8096 identifies both
the alarm and its source. This information is displayed on the Status web page
(which is the start-up page) and shows the current status of the unit. Specific
information for each device is accessed under Alarms on the Device Info tabbed
page (see Section 4.4).
Figure 4.1 Status Web Page
Table 4.1 to Table 4.3 describe the various fields on the web page.
Table 4.1 Alarm Source Identification
Parameter Description
Slot (Position)
Identifies the alarm source position in the system. This is typically
implemented by the slot number, but can be a pointer to any type
location in the unit.
Port Identifies a specific source within a position.
Table 4.2 Alarm Identification
Parameter Description
Alarm ID Unique number within the EQ8096 (see Section 4.5).
2/1553-FGC 101 1019 Uen A
4-3