Appendix
RX8200 Configuration Guide
xii
Figure 44 RX8200 Alarm Menu
Compatibility Vs Dynamic Mode Alarms
The current dynamic mode alarm functionality utilizes the next available incrementing identifier assigned at start-up.
These identifiers will change depending on the cards present in the unit configuration. The compatibility mode setting
allows pre-defined fixed identifiers to be assigned at startup. This in-turn allows the identifier of different units to be
tracked through the external control system consistently
Input
No TS Lock Choose the alarm condition from the drop-down menu to be activated when Transport Stream loses
lock (Set Alarm /No Alarm).
No TS Lock (relay mapping) Select the checkbox to activate relay mapping for Transport Stream loss of lock
alarm.
No Primary Input Lock Choose the alarm condition from the drop-down menu to be activated when Primary Input
loses lock (Set Alarm /No Alarm).
No Primary Input Lock (relay mapping) Select the checkbox to activate relay mapping for Primary Input loss of
lock alarm.
Monitor Inactive Input Select the checkbox to activate an alarm when there is no signal present at the Primary
Input .
No Secondary Input Lock Choose the alarm condition from the drop-down menu to be activated when Secondary
Input loses lock (Set Alarm /No Alarm).
No Secondary Input Lock (relay mapping) Select the checkbox to activate relay mapping for Secondary Input
loss of lock alarm.
C/N Margin Choose the alarm condition from the drop-down menu to be activated when the Carrier-to-Noise
margin, set below, is exceeded (Set Alarm /No Alarm).
C/N Margin (min value) Enter the Carrier-to-Noise margin minimum value in decibels. This is used to trigger the
alarm condition, set above, when exceeded.
C/N Margin (relay mapping) Select the checkbox to activate relay mapping for C/N Margin exceeded alarm.
Output
IPO Ethernet If 1/2 Down Choose the alarm condition from the drop-down menu to be activated when there is no
signal at IPO Ethernet 1/2 (Set Alarm /No Alarm).
IPO Ethernet If 1/2 Down (relay mapping) Select the checkbox to activate relay mapping for no signal at IPO
Ethernet 1/2.
Service
Video Not Running Choose the alarm condition from the drop-down menu to be activated when video is not
running (Set Alarm /No Alarm).
Video Not Running (relay mapping) Select the checkbox to activate relay mapping for video not running.