Installing the Equipment
Reference Guide: RX1290 H.264 Contribution Receiver Page 2-7
ST.RE.E10228.1
Figure 2.2: AC Power Inlet Assembly
NOTE...
See Annex B, Technical Specification for fuse information.
2.5.2 AC Power Supply Cord
General
A two-metre mains supply cord is supplied with this product. It is fitted with a moulded plug
suitable for the USA, UK or mainland Europe as advised at the time of ordering.
NOTE...
The equipment is not fitted with an a.c. power supply ON/OFF switch. Ensure the socket-outlet
supplying the equipment is installed near the equipment so that it is easily accessible.
Wire Colours
The wires in the supply cord are coloured as shown in Table 2.1.
Table 2.1: Supply Cord Wiring Colours
UK (BS 1363) EUROPE (CEE 7/7) USA (NEMA 5-15P)
Earth: Green-and-yellow Green-and-yellow Green
Neutral: Blue Blue White
Live: Brown Brown Black
If the colours do not correspond with the coloured markings identifying the terminals in a
locally supplied plug, proceed as in Table 2.2. The inclusion of Table 2.2 is for reference.
Table 2.2: Non Standard Supply Cord Wire Colours
Wire Colour (UK) Action
green-and-yellow ...must be connected to the terminal in the plug which is marked with the letter E or the safety earth
symbol or coloured green or green-and-yellow.
blue ...must be connected to the terminal in the plug which is marked with the letter N or coloured black.
brown ...must be connected to the terminal in the plug which is marked with the letter L or coloured red.
2.5.3 Connecting the Equipment to the AC Power Supply
As there is no mains power switch fitted to this unit, ensure the local a.c. power supply is
switched OFF before connecting the supply cord.
Connect the mains lead to the equipment and then to the local supply.
Position of the fuse carrier
Supply Inlet Mains