Installing the Equipment
Reference Guide: RX1290 H.264 Contribution Receiver Page 2-15
ST.RE.E10228.1
2.7.10 RS-232 Low-speed Asynchronous Data Output
A 9-way, D-type female connector provides a asynchronous
low-speed data serial communications interface. The status of the
data output on this connector is given in the Data menus (Menus 3.4
and 3.5).
Table 2.12: RS-232 Low-speed Data
Item Specification
Connector type 9-way, D-type, Female
Connector designation RS232 Data Out
Standards RS-232 DATA
Configuration DCE
Pin-outs
Pin 1 Reserved
Pin 2 Receive Data Output (RxD) (RS-232)
Pin 3 Reserved
Pin 4 No connection
Pin 5 Ground (RS-232)
Pin 6 Reserved
Pin 7 No connection
Pin 8 Reserved
Pin 9 Reserved
2.7.11 Serial Remote Control
A 9-way, D-type male connector provides a configurable
RS232/RS485 asynchronous low-speed data serial
communications interface for remote control.
Table 2.13: RS-232/RS485 Remote Control
Item Specification
Connector type 9-way, D-type, Female
Connector designation RS232/RS485 Remote
Standards RS-232 /RS-485
Configuration RS-232 RS-485
Pin-outs
Pin 1 Data Carrier Detect (DCD) - Input
Pin 2 Receive Data (RxD) - Input
Pin 3 Transmit Data (TXD) – Output
Pin 4 Data Terminal Ready - Output
Pin 5 Ground
Pin 6 Data Set Ready – Input
Pin 7 Request to Send - Output
Pin 8 Clear to Send - Input
Pin 9 Not connected
Pin 1 Not connected - Input
Pin 2 Not connected - Input
Pin 3 Not connected – Output
Pin 4 Rx - Input
Pin 5 Ground
Pin 6 Not Tx– Output
Pin 7 Tx - Output
Pin 8 Not Rx - Input
Pin 9 Not connected
2.8 Option Card Connectors
Option cards are described in Chapter 6, Options.
1 5
6 9
DATA
5
1
6 9
RS232/RS485 REMOTE
Seitenansicht 34