Operating the Equipment Locally
Reference Guide: RX1290 H.264 Contribution Receiver
Page 3-3
ST.RE.E10228.1
3.1 Powering the Equipment
3.1.1 Switching On
CAUTION...
This equipment should not be operated unless the cooling fan is working and there is free-air flow
around the unit.
Connect the signal inputs and a.c. power supply to the Contribution Receiver and power up
the unit. After a short period of initialisation and the Contribution Receiver gaining lock, the
unit powers up in Navigate mode. This is the usual operating condition.
The Lock LED will be on (green) when a signal is locked and off when unlocked. See
Figure 3.2 for the location of the Lock LED.
3.1.2 Power-up Operating Modes
No
IRD INITIALISING is displayed
during power-up. The Alarm LED
and Lock LED illuminate briefly
Yes
Secondary
Flash code
is loaded
Is the
RIGHT button
held in?
Power-up
Show SERVICE Menu (#3)
Initialisation
Local
Remote
NCP
What was
Control Mode at
Power Off?
REMOTE
CONTROL
NCP Command
Enter PIN
Only available when
VideoGuard is
installed and a valid
Smart Card inserted
TANDBERG
DIRECTOR
NCP
CONTROL
LOCAL
LOCKOUT
(LOCAL)
CONTROL
FRONT
PANEL
Figure 3.1: Power-up Operating Mode