Installing the Equipment
Page 2-14 Reference Guide: RX1290 H.264 Contribution Receiver
ST.RE.E10228.1
2.7.7 Ethernet
The equipment has an Ethernet remote control port for SNMP Control.
This is also used for high-speed data over Ethernet output and
TANDBERG engineering debug purposes.
Table 2.9: Ethernet Pin-outs
Item Specification
Connector type RJ-45 (100BaseT)
Connector designation 10/100BaseT
Pin-outs
(Unused pins not connected)
Pin 1 Tx Out (+)
Pin 2 Tx Out (-)
Pin 3 Rx In (+)
Pin 6 Rx In (-)
2.7.8 ASI IN
A BNC socket is provided for detection of the transport stream lock
on the ASI input.
Table 2.10: Digital Input Connector
Item Specification
Connector type BNC 75 Ω female socket
Connector designation ASI IN
Pin-outs Centre
Shield
ASI Input
Ground/Chassis
2.7.9 Alarm Connector and Relay
The alarm relay connector has a summary relay. The summary relay
is activated whenever the unit detects an alarm, or the power is
switched off.
Table 2.11: Alarm Connector
Item Specification
Connector type 9-way, D-type, Female for the summary alarm relay
Connector designation ALARM RELAY
Pin-outs Pin 1 - open
Pin 2 - open
Pin 3 - open
Pin 4 - Relay 1, common pin
Pin 5 - open
Pin 6 - open
Pin 7 - open
Pin 8 - Relay 1, Normally Closed (Open on Alarm)
Pin 9 - Relay 1, Normally Open (Closed on Alarm)
10/100BaseT
8
1
ASI IN
1 5
6 9
ALARM RELAY